Milbank – Powergen: Generators / 35-62kW Series

Features

35-62kW Series

Eliminate your loss from power outages with one of Milbank's commercial-sized standby generators.1 Supported by the best commercial warranty in the industry and an easy monitoring system, you can be confident, that when the power goes out, you won't be left in the dark. Designed to offer you more options for large homes and businesses with increasing electrical demands, commercial generators are part of a complete line of standby generators.

  • Comprehensive Commercial Warranty – Milbank offers a four-year limited warranty² that includes parts and labor. It’s one of the most comprehensive warranties in the commercial standby power industry.
  • Industrial-Grade GM Vortec™ Engine – This world class eight-cylinder GM Vortec™ engine operates at 1800 RPM - quieter and more fuel-efficient than 3600 RPM engines.
  • Longer Product Life – A commercial generator is a big investment. Designed with a longer life span, Milbank’s commercial standby generators have lower engine/alternator speeds, limited temperature rise on the alternator, and corrosion-resistant, all-metal enclosures.
  • Custom Built Options – A complete line of commercial standby generators for light commercial applications with multiple voltage, configuration and controller options available.
  • Power Management Technology – Used with our single-phase, liquid-cooled generators, Milbank’s automatic transfer switch harnesses our patented power management technology managing up to two load-dependent air conditioner units while keeping critical home or business applications powered.
  • Easier to Service – Convenient access points make it easier to service and provide immediate access to the entire engine without time-consuming disassembly.
  • Corrosion-Resistant Enclosure – Durable, all-metal enclosures are built to last protecting against extreme weather conditions and supported by the longest enclosure warranty in the industry.

Not for Prime Power or use where standby systems are legally required, for serious life safety or health hazards, or where lack of power hampers rescue of fire-fighting operations. ¹This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators). ²Warranty details available at milbankworks.com ³Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws, regulations and provided installation manual. Running engines give off carbon monoxide, an odorless, colorless, poisonous gas so it is important to keep exhaust gas away from any windows, doors, ventilation intakes or crawl spaces. The installation manual contains specific instructions related to generator placement in addition to NFPA 37, including the requirement that carbon monoxide detectors be installed and maintained in your home. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.

Controls

Standard Controller

  • User-friendly control panel for troubleshooting
  • Conveniently monitors diagnostic conditions, display system fault codes and sets weekly exercise cycle
  • Easy-to-read alpha-numeric scrolling display
  • Single-phase generator application only

InteliNano™ MRS Controller

  • Cost-effective controller that can be configured to application input, output, and parameter requirements
  • Large graphic display
  • Three-phase sensing
  • “Zero” power consumption mode
  • Easy installation and user-friendly operation
  • Ten-event history log
  • USB communication interface
  • UL recognized

InteliLite™ MRS 19 Controller

  • Integrated controller that fulfills requirements needed for MRS application
  • Remote control
  • User configuration
  • Complete gen-set monitoring and protection
  • Powerful graphic display
  • Easy troubleshooting with comprehensive history log
  • Operator-friendly analog gauge outputs (VOD, Datcon)
  • Remote control and monitoring capabilities
  • UL recognized
  • NFPA 110 capable controller

Extension Modules

(Sold separately; only work with 3Ø liquid-cooled models and InteliLite™ Controller)

 

Remote Annunciator | MG6267RA1

  • 15 programmable LEDs with configurable colors
  • Customizable labels
  • Local horn output
  • Lamp test function
  • UL certified

 

Remote Display | MG6266RD1

  • Mimics primary controller
  • Uses CAN communications

 

Accessories

35-62kW Series

  • Engine Block Heaters
    Designed for maximum engine performance, engine block heaters keep engines warm, allowing for faster and easier startups in cold weather. Milbank 35kW, 48kW and 62kW standby generators are tested to start at -20ºF using this kit. Each kit includes an engine block heater and bracket.

    35kW | MG624101 Engine block heater

    60kW & 62kW[3ø] | MG624201
    45 kw engine block heater
  • Maintenance Kits
    Complete with special UL air filter, pre-cleaner, spark plugs, oil filter and synthetic oil.

    35kW | MG300022 30 kw maintenance kit

    48kW[3], 60kW & 62kW[3ø] | MG450022 45 kw maintenance kit

  • Basic Wireless monitor | MG626401 (for use with 1Ø liquid-cooled models only)
  • infohub™ Wireless Monitoring | MG62601H1 (for use with 1Ø liquid-cooled models only)

35kW Models

Model Number Power (kW) Alternator Watts (LP) Amps (LP) Watts (NG) Amps (NG)
MG3524011BS 35 35-BSPP-0 35kW 146 31.5kW 131
MG3520831WIN 35 35-TBSPP-0 35kW 121 31.5kW 109
MG3524031WIN 35 35-TBSPP-0 35kW 105 31.5kW 95
MG3524031DIN 35 35-TBSPP-0 35kW 105 31.5kW 95
MG3548031WIN 35 35-TBSPP-0 35kW 53 31.5kW 47
MG3524011IL 35 35-BSPP-0 35kW 146 31.5kW 131
MG3520831WIL 35 35-TBSPP-0 35kW 121 31.5kW 109
MG3524031WIL 35 35-TBSPP-0 35kW 105 31.5kW 95
MG35244031DIL 35 35-TBSPP-0 35kW 105 31.5kW 95
MG3541631WIL 35 35-TBSPP-0 35kW 61 31.5kW 55
MG3548031WIL 35 35-TBSPP-0 35kW 53 31.5kW 47
Fuel Type Propane (LP) / Natural Gas (NG)
Limited Warranty 4 Years Parts and Labor (Limited)
Fuel Consumption† (½ load) 117 ft3/ hr / 3.1 gal/hr LP
282,000 BTU/hr NG
Fuel Consumption† (full load) 186 ft3/ hr / 4.9 gal/hr LP
458,800 BTU/hr NG
Alternator Type 4-Pole, Rotating Field
Alternator voltage Regulator Solid state, Volts/Hz
Engine Type GM Vortec 3.0L Industrial Powertrain
Dimension (L x W x H) 84.4” x 39.5” x 42.5”
Weight (generator only) 1469 lbs. / 666kg
Turnkey extras included Hour meter, battery charger, radiator fluid and oil

NOTE: These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.

†Fuel consumption rates are estimated based on normal operating conditions at 1/2 load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation.

48kW Models

Model Number Power (kW) Alternator Watts (LP) Amps (LP) Watts (NG) Amps (NG)
MG4824011BS 48 50-BSPP-0 48 kW 200 43.2kW 180
MG4820831WIN 48 50-TBSPP-0 48 kW 167 43.2kW 150
MG4824031WIN 48 50-TBSPP-0 48 kW 144 43.2kW 130
MG4824031DIN 48 50-TBSPP-0 48 kW 144 43.2kW 130
MG4848031WIN 48 50-TBSPP-0 48 kW 72 43.2kW 65
MG4824011L 48 50-BSPP-0 48 kW 200 43.2kW 180
MG4820831WIL 48 50-TBSPP-0 48 kW 167 43.2kW 150
MG4824031DIL 48 50-TBSPP-0 48 kW 144 43.2kW 130
MG4824031DIL 48 50-TBSPP-0 48 kW 144 43.2kW 130
MG4848031WIL 48 50-TBSPP-0 48 kW 72 43.2kW 65
Fuel Type Propane (LP) / Natural Gas (NG)
Limited Warranty 4 Years Parts and Labor (Limited)
Fuel Consumption† (½ load) 185 ft3/ hr / 4.8 gal/hr LP
429,000 BTU/hr NG
Fuel Consumption† (full load) 314 ft3/ hr / 8.2 gal/hr LP
717,000 BTU/hr NG
Alternator Type 4-Pole, Rotating Field
Alternator voltage Regulator Solid state, Volts/Hz
Engine Type GM Vortec 5.0L Industrial Powertrain
Dimension (L x W x H) 94.4” x 39.5” x 44.5”
Weight (generator only) 1890 lbs. / 857kg
Turnkey extras included Hour meter, battery charger, radiator fluid and oil

NOTE: These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.

†Fuel consumption rates are estimated based on normal operating conditions at 1/2 load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation.

62kW Models

Model Number Power (kW) Alternator Watts (LP) Amps (LP) Watts (NG) Amps (NG)
MG6024011BS 62 60-BSPP-0 60kW 250 54kW 225
MG6220831WIN 62 60-TBSPP-0 62kW 215 55.8kW 194
MG6224031WIN 62 60-TBSPP-0 62kW 186 55.8kW 168
MG6224031DIN 62 60-TBSPP-0 62kW 186 55.8kW 168
MG6248031WIN 62 60-TBSPP-0 62kW 93 55.8kW 84
MG6024011IL 62 60-BSPP-0 62kW 250 54kW 225
MG6220831WIL 62 60-TBSPP-0 62kW 215 55.8kW 194
MG6224031WIL 62 60-TBSPP-0 62kW 186 55.8kW 168
MG6224031DIL 62 60-TBSPP-0 62kW 186 55.8kW 168
MG6248031WIL 62 60-TBSPP-0 62kW 93 55.8kW 110
Fuel Type Propane (LP) / Natural Gas (NG)
Limited Warranty 4 Years Parts and Labor (Limited)
Fuel Consumption† (½ load) 200 ft3/ hr / 5.2 gal/hr LP
463,000 BTU/hr NG
Fuel Consumption† (full load) 345 ft3/ hr / 9.0 gal/hr LP
788,000 BTU/hr NG
Alternator Type 4-Pole, Rotating Field
Alternator voltage Regulator Solid state, Volts/Hz
Engine Type GM Vortec 5.7L Industrial Powertrain
Dimension (L x W x H) 98.4” x 39.5” x 44.5”
Weight (generator only) 2120 lbs. / 962kg
Turnkey extras included Hour meter, battery charger, radiator fluid and oil

NOTE: These generators are rated in accordance with UL 2200 and CSA Standard C22.2 No. 100-04. Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances - fuel flow rates may vary depending on these factors. Installations must strictly comply with all applicable codes, industry standards, laws and regulations, installation manual. Other Generator/Automatic Transfer Switch manufacturers products are not compatible with Milbank Home Generator Systems. Improper installation voids all warranty. Milbank reserves the right to make changes in specifications and features shown without notice or discontinue the product described at any time without notice or obligation.

†Fuel consumption rates are estimated based on normal operating conditions at 1/2 load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation.