Meter Mains Compliant with NEC 2020
As NEC 2020 starts to be adopted across the country, single- and two-position residential meter sockets will need an emergency disconnect. Milbank offers multiple meter mains that can serve as the right solution for your project. Several meter mains with load centers are shown here that meet NEC 2020 sections 230.62 enclosed or guarded service equipment requirement and 230.85(1) emergency disconnect requirement.
If you’re looking for a product or have questions, contact your local rep or Milbank technical support. Be sure to check with your local utilities for Milbank meter mains approved in your area. Learn more about NEC 2020 changes applicable to Milbank products. Looking for more meter mains? Read on about Milbank 400 Amps meter mains.
Below are different meter mains that Milbank offers including those with load centers, those without load centers and two-position meter mains.
Meter Mains with Load Centers
Features for the examples shown:
- 100-200 Amps
- Extra branch circuits
- Lever, horn and no bypass options
- Ringless and ring type
- Feed-through lugs
- Interlock kits available for generator backup power
- K5815, K5820, K5830 for different breaker size needs
- Overhead/underground entry and exit
- G90 galvanized steel with powder coat finish
- Single phase
- NEMA 3R enclosure
- UL listed
- Manufactured in the USA
U6281
*Available in ring type
Meter Mains without Load Centers
Features for the examples shown:
- 100-200 Amps
- Horn, lever and no bypass options
- Ringless and ring type
- Feed-through lugs
- Overhead/underground entry and exit on U5844; overhead only on U5842
- G90 galvanized steel with powder coat finish
- Single phase
- NEMA 3R enclosure
- UL listed
- Manufactured in the USA
U5844*
U5842*
*Available in ring type
U5882
Two-position Meter Mains
- 100-200 Amps
- Horn, lever and no bypass options
- Ringless and ring type
- Overhead/underground entry and exit
- G90 galvanized steel with powder coat finish
- Single phase
- NEMA 3R enclosure
- UL listed
- Manufactured in the USA
Addressing Specific Sections of NEC 2020
The products on this page have been approved to meet NEC 2020 compliance in some areas. Below are examples of some of the changes that were made to meet compliance. To learn about specific solutions for your region, contact your local Milbank representative. Local authorities approve installations and determine if products are NEC 2020 compliant based on local regulations and interpretations. Always check with local inspectors and utilities to ensure a product is approved in your area.
Insulator compliant with NEC 230.62
Example of insulator available on the 200 Amps U5168 product line, insulators on other meter mains could be different.
Aluminum bus compliant with NEC 230.62
Example of aluminum bus available on some Milbank products.
Label compliant with NEC 230.85
Watch a Milbank product expert explain the relevant NEC 2020 changes for Milbank product and the steps we've taken to address those updates.